ResMed AirSense 11 - Complete Guide 2026
The AirSense 11 is ResMed's latest generation CPAP/Auto CPAP device. Available in two versions - AutoSet and Elite - it is in 2025 the benchmark for therapeutic efficacy, connectivity and comfort. This guide explains everything you need to know to make the right choice.
AirSense 11 AutoSet or Elite: which one?
The AutoSet adjusts pressure night after night between two limits. The Elite delivers one fixed pressure. If your optimal pressure has not been established yet, or if it shifts with position and weight, take the AutoSet. If your prescription sets a specific value and it suits you, the Elite is enough and costs less.
| AirSense 11 AutoSet | AirSense 11 Elite | |
|---|---|---|
| Pressure mode | Auto, between a lower and an upper limit | Fixed, a single value |
| AutoSet-14 algorithm | Yes | No |
| EPR, humidification, myAir | Yes | Yes, identical |
| Prescribed when | Optimal pressure is unknown or variable | Optimal pressure is known and stable |
| Price | Higher | Lower |
What is AutoSet mode?
AutoSet is ResMed's automatic mode. Instead of blowing a constant pressure, the device measures your breathing twenty-five times a second. It raises pressure when it detects the start of an obstruction, snoring or flow limitation, then lowers it once the airway is clear. You set nothing yourself: you only set the limits.
Where do you find the AirSense 11 user manual?
The official user guide is a multilingual PDF published by ResMed: AirSense 11 user guide. A copy also ships with the device.
For day-to-day handling our tutorials go further: they show the exact AirSense 11 screen at each step, which the manual does not.
The most consulted: setting the ramp, setting humidification and changing the filter. The full list is further down this page.
The two models in detail
- Auto CPAP mode: pressure adjusted in real time
- AutoSet-14 algorithm: detects apneas, hypopneas, snoring and RERAs
- Intelligent leak management
- Automatic data transmission + myAir app
- Integrated ClimateControl Auto
- Compatible with HumidAir 11 and ClimateLineAir 11
- Fixed pressure mode (classic CPAP)
- Prescribed when optimal pressure is already established
- Same comfort features (EPR, humidification)
- Identical data transmission and myAir
- Slightly lower price than AutoSet
- Compatible with the same accessories
The AutoSet-14 Algorithm: how does it work?
The core of the AirSense 11 AutoSet is its AutoSet-14 algorithm, developed and patented by ResMed. Every 14 milliseconds, the device analyses the breathing signal and adapts the delivered pressure. It detects:
- Obstructive apneas: complete upper airway obstruction
- Hypopneas: partial reduction in airflow
- Snoring: early indicator of partial obstruction
- RERAs (Respiratory Effort Related Arousals): micro-arousals linked to breathing effort
In response, pressure gradually increases to open the airway, then decreases once breathing normalises. The result: pressure that is always appropriate - not too high (discomfort) and not too low (persistent apneas).
Data Transmission and the myAir App
The AirSense 11 sends your data on its own, with no network to configure. Each night, therapy data goes automatically to ResMed servers. You can review it via the myAir app (iOS and Android):
- Daily therapy score (out of 100 points)
- Residual AHI, leak index, hours of use
- Personalised tips to improve adherence
- Data shareable with your doctor or sleep specialist
ClimateControl Auto and Smart Humidification
Humidification is crucial for long-term CPAP tolerance. The AirSense 11 offers:
- ClimateControl Auto: automatically adjusts humidifier and heated tube warmth based on ambient temperature
- HumidAir 11: integrated washable humidifier, exclusively compatible with AirSense 11
- ClimateLineAir 11: dedicated 15 HT heated tube, eliminates condensation in the circuit
Mask Compatibility
The AirSense 11 is compatible with the full ResMed AirFit and AirTouch mask range, as well as masks from other brands (standard 22 mm connection). Most popular masks with this device:
RIZIV/INAMI Convention in Belgium
In Belgium, the INAMI/RIZIV convention for CPAP is reserved for patients with an AHI ≥ 15 (moderate to severe apnea), managed through an accredited sleep centre. Under this system, the device is provided on loan - the patient never becomes the owner.
VivaRespire offers a direct purchase alternative, outside the convention. The right solution for:
- People with AHI < 15 (not covered by INAMI)
- Those who want to freely choose their device and mask
- Those who want to start immediately, without administrative delays
- Travellers and expatriates
Order your AirSense 11 from VivaRespire
Fast delivery to Belgium, France and Luxembourg. Francophone support. Easy returns.
Recommended Accessories
- ClimateLineAir 11 heated tube - eliminates condensation
- HumidAir 11 Cleanable - dishwasher-safe humidifier
- Medistrom Pilot-24 Lite Battery - travel and camping
- Browse all CPAP masks
Setting this device day to day
Our step by step tutorials, with the exact procedure on each device:
- Setting the ramp
- Setting humidification and tube temperature
- EPR and SmartStart: what you set yourself
- Running the mask fit test
- Cleaning and maintaining your device
- Replacing the air filter
- SD card, myAir and therapy data
- Turning on airplane mode
Frequently asked questions about AirSense 11 AutoSet vs Elite
The hardware is identical: same enclosure, same display, same connectivity, same accessories. The difference is software. The AutoSet runs in Auto CPAP mode: it adjusts pressure in real time based on your breathing. The Elite runs in fixed pressure mode: it delivers the prescribed pressure with no automatic adaptation. The Elite is prescribed when the optimal pressure is already known after lab titration.
In almost all out-of-convention cases, AutoSet is the right choice. You typically don't have a precise titrated pressure from a sleep centre, and the AutoSet algorithm finds the effective pressure on its own, night after night. The Elite only makes sense if you have a clear fixed-pressure prescription or very stable apnea. For 95 percent of out-of-convention patients, it's AutoSet.
AutoSet-14 is an evolution of the original AutoSet algorithm. ResMed reports improvements in fine event detection and mask leak management. In the field, patients moving from AirSense 10 to 11 report equivalent or slightly better comfort, but rarely a dramatic difference. The real value of AS11 comes mostly from automatic data transmission and the enhanced myAir ecosystem.
Yes to both. myAir is the official ResMed app (iOS and Android), paired to the device over Bluetooth, showing your therapy score, residual AHI, leaks and hours of use. OSCAR is a free, open-source software that reads data through the SD card inserted in the device. OSCAR delivers a much deeper analysis, useful for users who want to optimise their therapy.
ClimateControl Auto is included as standard in the AirSense 11, there is no extra cost. It automatically adjusts tube warmth and humidification based on ambient temperature. It's very useful in winter to avoid condensation, and in summer to prevent overheating. You keep the option to switch to manual mode if you prefer to set temperature and humidity yourself.
Yes, all ResMed AirFit and AirTouch masks work seamlessly on AirSense 10 and 11 thanks to the standard 22 mm connection. However, the tube and humidifier are not compatible between the two generations. You will need to use the ClimateLineAir 11 and HumidAir 11 specific to AirSense 11. Factor in that cost if you upgrade from AS10 to 11.
A prescription is not legally required to buy a CPAP in Belgium. We strongly recommend a prior medical diagnosis (polysomnography or polygraphy) and your doctor's input on the pressure range to program. This avoids using an unsuitable pressure. If you already have a sleep centre report, send it to us so we can correctly configure the device before shipping.